Birm Iron Filter System with 9

Birm Iron Filter System with 9" X 48" Tank & Fleck 2510SXT OCS Digital Control Valve

Birm Iron Filter & Fleck 2510SXT AIO Digital Control Valve

Birm Iron Filter & Fleck 2510SXT AIO Digital Control Valve

Birm Iron Filter System & Aqua Science Eco Advanced Plus AIO OCS Digital Control Valve

Lifetime Warranty
CLICK HERE TO CONFIRM THE PRICE
MSRP $1,902.00
Sale Price $951.00
50% OFF Factory Direct Saving
SKU#
BIRMAS89OCS
In stock
Free Shipping
Only %1 left
BIRMAS89OCS

Helps to Remove
Iron and Manganese

Advantages
•Under the proper conditions, no chemicals to purchase for maintenance. Regeneration is not required.
•Iron removal efficiency is extremely high.
•Negligible labor cost: only periodic backwashing is required.
•Durable material with a long life and wide temperature range.
•Weighs only 36-38 lbs./cu.

Click to Read More about Birm

Birm is a Granular filter media used for the removal of Iron and Manganese. It is an efficient and economical method of removing dissolved iron and manganese compounds from raw water supplies. Birm works at maximum efficiency with pH levels of 7.2 or greater.

This system includes:

Aqua Science Digital Control Valve
9x48 Fiberglass Mineral Tank
1" by-pass
1 Cu. ft of Birm
1 Sleeve of gravel
1.05" Riser Tube
Funnel and Cap 
 

Birm is an efficient and economical media for the reduction of dissolved iron and manganese compounds from raw water supplies. It may be used in either gravity-fed or pressurized water treatment systems. Birm acts as an insoluble catalyst to enhance the reaction between dissolved oxygen (D.O.) and iron compounds. In ground waters, the dissolved iron is usually in the ferrous bicarbonate state due to the excess of free carbon dioxide and is not filterable. Birm, acting as a catalyst between the oxygen and the soluble iron compounds, enhances the oxidation reaction of Fe++ to Fe+++ and produces ferric hydroxide which precipitates and may be easily filtered. The physical characteristics of Birm provide an excellent filter media that is easily cleaned by backwashing to remove the precipitant. Birm is not consumed in the iron removal operation and therefore offers a tremendous economic advantage over many other iron removal methods.

Other advantages of Birm include; long material life with relatively low attrition loss, a wide temperature performance range, and extremely high removal efficiency. Negligible labor costs are involved because Birm does not require chemicals for regeneration, only periodic backwashing is required.

When using Birm for iron removal, it is necessary that the water: contains no oil or hydrogen sulfide, organic matter not to exceed 4-5 ppm, the D.O. content equals at least 15% of the iron content with a pH of 6.8 or more. If the influent water has a pH of less than 6.8, neutralizing additives such as Clack Corosex®, Calcite, or soda ash may be used before the Birm filter to raise the pH. Water having a low D.O. level may be pretreated by aeration.

More Information
MaterialBirm
Control ValveAS89
Model #BIRMAS89OCS
ManufacturerAqua Science
Performance ChartNone
Shipping Weight152
Write Your Own Review
You're reviewing:Birm Iron Filter System & Aqua Science Eco Advanced Plus AIO OCS Digital Control Valve
Your Rating
What does the Birm Iron Filter System remove?
It removes dissolved iron and manganese from water supplies.
What are the ideal conditions for using Birm media?
The pH should be 7.2 or greater, with no oil or hydrogen sulfide, and organic matter should not exceed 4-5 ppm.
Does the Birm media require regeneration?
No, Birm does not require chemical regeneration, only periodic backwashing.
What components are included in the system?
The system includes a digital control valve, fiberglass mineral tank, bypass, Birm media, gravel, riser tube, funnel, and cap.
Can the Birm system handle low pH water?
Yes, but you may need to use neutralizing additives like Clack Corosex®, Calcite, or soda ash to raise the pH.
Is the Birm media consumed during the filtration process?
No, Birm acts as a catalyst and is not consumed, offering economic advantages.
What maintenance is required for the Birm system?
Only periodic backwashing is needed to clean the filter media.

Installation Brief

Installation of the Birm Iron Filter System should be performed by a professional to ensure optimal performance and safety.

  1. Connect the system to the main water supply.
  2. Ensure the pH and dissolved oxygen levels meet the required conditions.
  3. Install the digital control valve and set the appropriate settings.
  4. Perform a backwash to prepare the system for use.
Important:
  • Ensure water does not contain oil or hydrogen sulfide.
  • Check that organic matter does not exceed 4-5 ppm.
  • Verify that the pH is 6.8 or higher before installation.
Birm Iron Filter System & Aqua Science Eco Advanced Plus AIO OCS Digital Control ValveBirm Iron Filter System & Aqua Science Eco Advanced Plus AIO OCS Digital Control Valve