Maintains consistent water pressure automatically
Improves system efficiency by matching pump speed to demand, which can save energy and make the RD300 a cost effective solution for matching pump output to demand
Reduces pressure fluctuations during varying water usage
Helps protect pumps from damaging operating conditions with built-in safeguards against dry-running and motor overloads for submersible well pump systems
The controller can detect a dry run event within a few seconds after a brief delay under a low-power condition and turn off power within seconds to help avoid damage if the pump continues to run without water. It can act on low-power readings over a defined period and delay time to help prevent false shutdowns.
During setup, some parameters may need to be tune adjusted, and a timer-based delay helps prevent nuisance trips.
Provides detailed system monitoring and diagnostics
Suitable for residential, agricultural, and commercial applications
Weather-resistant enclosure supports flexible installation options
Installation Brief
Mount the control panel in a suitable indoor or outdoor location.
Install the included 0–150 PSI pressure transducer in the water system.
Connect the controller to the appropriate power supply.
Complete wiring connections to the compatible three-phase submersible pump according to local electrical codes and manufacturer instructions.
Configure the desired pressure settings using the LCD display interface, then save the settings.
Verify system operation and check that the pump started and is working correctly while monitoring pressure, pump status, and system performance through the display.
The H2O Drive RD300 is a constant pressure control panel for three-phase submersible well pump applications. It uses a variable frequency drive and a 0-150 PSI pressure transducer to adjust pump speed as system demand changes, operate automatically as demand changes, and maintain the selected pressure when multiple outlets are in use. In high-performance water systems, reliability, quality, and technical support matter just as much as pressure control. A color LCD display supports setup and monitoring with pressure, pump speed, amps, status, alarms, and alarm history, so homeowners, farm operators, contractors, and commercial users can see the key information needed to run the system correctly.
A dry run condition means the pump is running dry with low or no water flow, which can cause permanent damage to the pump, impeller, bearings, and the cooling of internal components.
Dry run protection is an important safeguard that uses current-sensing or power-based monitoring of the active power value to detect low flow and shut the pump to stop damage and overheating, providing reliable protection. There are different methods for detecting dry run, and the recommended setup depends on having the right information in mind during installation and adjustment. A motor replacement costs significantly more than dry-run protection, which is one of the clear advantages of built-in protection.
The H2O Drive RD300 is a state-of-the-art constant pressure controller designed to enhance the performance of your submersible well pumps. Utilizing advanced Variable Frequency Drive (VFD) technology, this controller ensures stable water pressure in residential, agricultural, or commercial water systems by automatically adjusting the pump speed according to water demand. This function helps water pumps in wells maintain steady pressure and prevent drops when several fixtures are used at once. In this overview, you’ll see the main benefits of the RD300, how its dry-run protection and LCD monitoring work, and what to keep in mind for installation and system setup. A traditional pump system may also rely on a pressure switch and larger tank, while a VFD controller can reduce dependence on those components. Private well systems can be subject to changing source conditions, which leads to dry-run risk and makes protection important for long-term reliability.
The integrated color LCD display provides access to:
System pressure (PSI)
Pump speed (Hz)
Motor amperage
Pump running status
Alarm notifications
Alarm history
System alerts and diagnostics
Model #: RD300
Horsepower compatibility: 2 to 3 HP for high performance applications, with reliability prioritized as a key spec
Shipping Weight: 18 lbs
Operates on 200–240V single-phase input, converts to 208/230V three-phase output.
Enclosure rating: nema 3R, for indoor and outdoor installations where manual reset is required. this may also be needed when replacing components or controllers after a shutoff event
| Source | https://www.sjerhombus.com/ |
|---|---|
| Model # | RD300 |
| Manufacturer | Aqua Science |
| Performance Chart | None |
| Shipping Weight | 18 |

The H2O Drive RD300 is set up to control pump speed and maintain a selected pressure in constant pressure applications.