Call for Best Shipping Price

Goulds Balanced Flow Constant Pressure System, 5HP Motor 18GPM @60PSI - 550ft

CLICK HERE TO CONFIRM THE PRICE
MSRP $8,702.00
Sale Price $6,592.00
24% OFF Factory Direct Saving
SKU#
18GP3050
In stock
18GP3050

Product Specifications

Model #: 18GP3050

Manufacturer: Goulds

Warranty: 3 Year Limited

Motor Horsepower: 5 HP

Flow Rate: 18 GPM

Amps: 16.6

Volts: 230V

Phase: 3

Wire Count: 3 Wire

Well Depth: 550 ft

Shipping Weight: 101 lbs

Universal Product Code: 69766653419

Key Features

  • Simple, fast sizing and installation, including checking outlet or pipe size for a proper fit.

  • Range curves and selection charts generated from actual R&D tests for comparing similar well pumps.

  • Kits configured to run within a 30 Hz minimum and 80 Hz maximum operating frequency range.

  • Wiring is as easy as standard three-wire control box: (1) L1, L2 and Ground in from power supply (2)Red, Yellow, Black and Ground out to motor; setup help is also available on YouTube.

  • Pressure is factory preset at 50 psi with simple, fast, field adjustability for higher pressures, helping reduce pressure fluctuation pain points that can add system strain.

  • Three phase output to motor reduces wire cost.

  • Goulds model GS features the Guardian bearing system to protect components inside the pump from sand and abrasives and help extend service life.

  • New – a Switch Input for connecting a pressure switch or float switch.

  • New – Grounding provisions for transducer and transducer cable.

Goulds Balanced Flow Constant Pressure System model 18GP3050 is a submersible well pump system ProPak kit with a 5 HP, 230V three-phase CentriPro motor, Aquavar SOLO controller with transducer, and Goulds GS water.

Designed for residential and agricultural water wells, it helps customers find the right fit for well depth, pressure needs, and pressure tanks across a wide range of well pump applications and other submersible pump setups. This system is rated for 18 GPM at 60 PSI and well depths up to 550 ft. It is designed to provide consistent water pressure and reliable pressure for agricultural uses and irrigation, helping support clean water delivery where steady performance matters. Its design enables operation with a smaller inline pressure tank, and it features a wall-mounted NEMA 3 controller that can be mounted outside.

Balanced Flow Controller – NEW FEATURES for Higher Pressures:

  • New, more versatile user interface board that combines key components in one system to simplify installation

  • Provides switch connection for an optional pressure or level switch as a useful step when you plan the setup, and you can hear setup guidance through support resources if needed

  • New current limit settings for all new CentriPro motors

  • Built-in protections include dry-well sensitivity for more reliable operation

  • Built-in protections also include broken pipe detection for easier troubleshooting

  • These safeguards help support reliable working operation and make troubleshooting easier, with customer feedback helping improve support when customers need it.

  • 5 or 20 PSI pressure drop restart switch

  • Transducer better protected from transient power surges

Transducer – NEW AND IMPROVED for Pressure Tank:

  • Larger port orifice to prevent clogging

  • Case to electronics surge protection

  • All Stainless Steel construction for the submersible pump/transducer assembly, built for long-term durability and resistance to leaks around the assembly

  • Pressure surge capability without the use of a pressure snubber

  • Case coupled noise immunity

  • Reverse voltage protection

  • Line to electronics ground surge protection on all lines

  • Transducer cable has ground wire built-in to help you learn what the upgraded transducer content means in practical use: simpler grounding and more reliable signal performance

  • Ground clamp provided for transducer to cable grounding

Related Posts

Why should a homeowner consider a Constant Pressure system for home applications?

Product Literature

Aquavar SOLO2 Installation Guide

Goulds Aquavar Installation and Troubleshooting

Goulds Aquavar Propak Brochure

Goulds Aquavar Propak, 30-80hz Specifications

Goulds Aquavar Solo 2 Instruction Manual

Goulds Variable Speed Controller Hazard Statement

Technical Brochure

More Information
Phase3
Wire Count3 Wire
Motor Horsepower5
Flow Rate18
Stages 19
Well Depth550
Sourcehttps://www.xylem.com/
Model #18GP3050
ManufacturerGoulds
Performance ChartNone
Shipping Weight101
Warranty3 Year Limited
Write Your Own Review
You're reviewing:Goulds Balanced Flow Constant Pressure System, 5HP Motor 18GPM @60PSI - 550ft
Your Rating
Goulds Balanced Flow Constant Pressure System, 5HP Motor 18GPM @60PSI - 550ft
What is the flow rate of this system?
This system is rated for 18 GPM.
What motor size does it use?
It uses a 5 HP CentriPro three phase motor.
What well depth is this system designed for?
It is designed for wells up to 550 feet.
What is the pressure setting from the factory?
Pressure is factory preset at 50 psi and can be adjusted for higher pressures.
What pressure adjustment range is stated for the system?
The product description states 0 to 100 PSI pressure setting with finger controlled adjustments.
Does this system require a large pressure tank?
No. The product description states only a small inline pressure tank is needed.
Can the controller be mounted outside?
Yes. The wall mounted controller is described as NEMA 3 rated and can be mounted outside.
What wiring connections are listed?
The listed wiring is L1, L2, and Ground in from the power supply, with Red, Yellow, Black, and Ground out to the motor.

Installation Brief

This constant pressure system combines the pump, motor, controller, and transducer into a packaged setup for well system installation.

  1. Mount the wall mounted NEMA 3 rated controller in the intended location.
  2. Connect L1, L2, and Ground from the power supply to the controller.
  3. Connect Red, Yellow, Black, and Ground from the controller to the motor.
  4. Confirm the transducer and related grounding provisions are connected as specified for the system.
  5. Start the system and verify the pressure setting, which is factory preset at 50 psi and field adjustable for higher pressures.
Goulds Balanced Flow Constant Pressure System, 5HP Motor 18GPM @60PSI - 550ftGoulds Balanced Flow Constant Pressure System, 5HP Motor 18GPM @60PSI - 550ft