Product Specifications

Model #: 18GP1020

Manufacturer: Goulds

Warranty: 3 Year Limited

Motor Horsepower: 2 HP

Flow Rate: 18 GPM

Amps: 6.9

Volts: 230V

Phase: 3

Wire Count: 3 Wire

Well Depth: 170 ft

Shipping Weight: 61 lbs

Universal Product Code: 69766653414

Key Features

  • Simple, fast sizing and installation, including checking outlet or pipe size for a proper fit.

  • Range curves and selection charts generated from actual R&D tests for comparing similar well pumps.

  • Kits configured to run within a 30 Hz minimum and 80 Hz maximum operating frequency range.

  • Wiring is as easy as standard three-wire control box: (1) L1, L2 and Ground in from power supply (2)Red, Yellow, Black and Ground out to motor; setup help is also available on YouTube.

  • Pressure is factory preset at 50 psi with simple, fast, field adjustability for higher pressures, helping reduce pressure fluctuation pain points that can add system strain.

  • Three phase output to motor reduces wire cost.

  • Goulds model GS features the Guardian bearing system to protect components inside the pump from sand and abrasives and help extend service life.

  • New – a Switch Input for connecting a pressure switch or float switch.

  • New – Grounding provisions for transducer and transducer cable.

Overview

Goulds Balanced Flow Constant Pressure System model 18GP1020 is a submersible well pump system ProPak kit with a 2 HP, 230V three-phase CentriPro motor, Aquavar SOLO controller with transducer, and Goulds GS water.

Designed for residential and agricultural water wells, it helps customers find the right fit for well depth, pressure needs, and pressure tanks across a wide range of well pump applications and other submersible pump setups. This system is rated for 18 GPM at 60 PSI and well depths up to 170 ft. It is designed to provide consistent water pressure and reliable pressure for agricultural uses and irrigation, helping support clean water delivery where steady performance matters. Its design enables operation with a smaller inline pressure tank, and it features a wall-mounted NEMA 3 controller that can be mounted outside.

Balanced Flow Controller – NEW FEATURES for Higher Pressures:

  • New, more versatile user interface board that combines key components in one system to simplify installation

  • Provides switch connection for an optional pressure or level switch as a useful step when you plan the setup, and you can hear setup guidance through support resources if needed

  • New current limit settings for all new CentriPro motors

  • Built-in protections include dry-well sensitivity for more reliable operation

  • Built-in protections also include broken pipe detection for easier troubleshooting

  • These safeguards help support reliable working operation and make troubleshooting easier, with customer feedback helping improve support when customers need it.

  • 5 or 20 PSI pressure drop restart switch

  • Transducer better protected from transient power surges

Transducer – NEW AND IMPROVED for Pressure Tank:

  • Larger port orifice to prevent clogging

  • Case to electronics surge protection

  • All Stainless Steel construction for the submersible pump/transducer assembly, built for long-term durability and resistance to leaks around the assembly

  • Pressure surge capability without the use of a pressure snubber

  • Case coupled noise immunity

  • Reverse voltage protection

  • Line to electronics ground surge protection on all lines

  • Transducer cable has ground wire built-in to help you learn what the upgraded transducer content means in practical use: simpler grounding and more reliable signal performance

  • Ground clamp provided for transducer to cable grounding

Related Posts

Why should a homeowner consider a Constant Pressure system for home applications?

Product Literature

Aquavar SOLO2 Installation Guide

Goulds Aquavar Installation and Troubleshooting

Goulds Aquavar Propak Brochure

Goulds Aquavar Propak, 30-80hz Specifications

Goulds Aquavar Solo 2 Instruction Manual

Goulds Variable Speed Controller Hazard Statement

Technical Brochure

More Information
Phase3
Wire Count3 Wire
Motor Horsepower2
Flow Rate18
Stages 8
Well Depth170
Sourcehttps://www.xylem.com/
Model #18GP1020
ManufacturerGoulds
Performance ChartNone
Shipping Weight61
Warranty3 Year Limited
Write Your Own Review
You're reviewing:Goulds Balanced Flow Constant Pressure System, 2HP Motor 18GPM @60PSI - 170ft
Your Rating
Goulds Balanced Flow Constant Pressure System, 2HP Motor 18GPM @60PSI - 170ft
What flow rate does this system provide?
It is rated for 18 GPM at 60 PSI.
What motor is included in this ProPak kit?
The kit includes a CentriPro three-phase 2 HP, 230 V motor.
What pump is included with this system?
It includes a Goulds GS water end, model 18GS10.
What controller is included?
The system includes a CentriPro Aquavar SOLO controller with transducer, model 3AS20.
Is a large pressure tank required?
No. The system is designed to use only a small inline pressure tank.
Can the controller be mounted outside?
Yes. The wall-mounted controller is NEMA 3 rated and can be mounted outside.
What pressure range can be adjusted on this system?
The pressure setting is adjustable from 0 to 100 PSI, and features simple field adjustability.
What diagnostic protections are included?
The self-diagnostic controls check for dry well, ground fault, short circuit, disconnected lead, high pressure sensor, and temperature fault.

Installation Brief

This constant pressure system should be installed according to the supplied product instructions and applicable local codes.

  1. Review the included system components, including the motor, controller with transducer, and pump water end.
  2. Mount the wall-mounted controller in an appropriate location; the product data states the NEMA 3 controller can be mounted outside.
  3. Complete the required power and motor wiring using the product's stated wiring layout: L1, L2, and ground from the power supply, and red, yellow, black, and ground out to the motor.
  4. Set the desired pressure using the controller's field-adjustable pressure setting.
  5. Verify the system is operating properly and confirm the controller shows normal operation without diagnostic faults.