Call for Best Shipping Price

Goulds Balanced Flow Constant Pressure System, 1.5HP Motor 10GPM at 60PSI - 240ft

CLICK HERE TO CONFIRM THE PRICE
MSRP $5,922.50
Sale Price $2,961.25
50% OFF Factory Direct Saving
SKU#
10GP0715
In stock
10GP0715

Product Specifications

Model #: 10GP0715

Manufacturer: Goulds

Warranty: 3 Year Limited

Motor Horsepower: 1.5 HP

Flow Rate: 10 GPM

Amps: 4.2

Volts: 230V

Phase: 3

Wire Count: 3 Wire

Well Depth: 240 ft

Shipping Weight: 56 lbs

Universal Product Code: 69766653413

Key Features

  • Simple, fast sizing and installation, including checking outlet or pipe size for a proper fit.

  • Range curves and selection charts generated from actual R&D tests for comparing similar well pumps.

  • Kits configured to run within a 30 Hz minimum and 80 Hz maximum operating frequency range.

  • Wiring is as easy as standard three-wire control box: (1) L1, L2 and Ground in from power supply (2)Red, Yellow, Black and Ground out to motor; setup help is also available on YouTube.

  • Pressure is factory preset at 50 psi with simple, fast, field adjustability for higher pressures, helping reduce pressure fluctuation pain points that can add system strain.

  • Three phase output to motor reduces wire cost.

  • Goulds model GS features the Guardian bearing system to protect components inside the pump from sand and abrasives and help extend service life.

  • New – a Switch Input for connecting a pressure switch or float switch.

  • New – Grounding provisions for transducer and transducer cable.

Overview

Goulds Balanced Flow Constant Pressure System model 10GP0715 is a submersible well pump system ProPak kit with a 1.5 HP, 230V three-phase CentriPro motor, Aquavar SOLO controller with transducer, and Goulds GS water.

system includes AquaScience 8% Crosslink Resin.

Designed for residential and agricultural water wells, it helps customers find the right fit for well depth, pressure needs, and pressure tanks across a wide range of well pump applications and other submersible pump setups. This system is rated for 10 GPM at 60 PSI and well depths up to 240 ft. It is designed to provide consistent water pressure and reliable pressure for agricultural uses and irrigation, helping support clean water delivery where steady performance matters. Its design enables operation with a smaller inline pressure tank, and it features a wall-mounted NEMA 3 controller that can be mounted outside.

Balanced Flow Controller – NEW FEATURES for Higher Pressures:

  • New, more versatile user interface board that combines key components in one system to simplify installation

  • Provides switch connection for an optional pressure or level switch as a useful step when you plan the setup, and you can hear setup guidance through support resources if needed

  • New current limit settings for all new CentriPro motors

  • Built-in protections include dry-well sensitivity for more reliable operation

  • Built-in protections also include broken pipe detection for easier troubleshooting

  • These safeguards help support reliable working operation and make troubleshooting easier, with customer feedback helping improve support when customers need it.

  • 5 or 20 PSI pressure drop restart switch

  • Transducer better protected from transient power surges

Transducer – NEW AND IMPROVED for Pressure Tank:

  • Larger port orifice to prevent clogging

  • Case to electronics surge protection

  • All Stainless Steel construction for the submersible pump/transducer assembly, built for long-term durability and resistance to leaks around the assembly

  • Pressure surge capability without the use of a pressure snubber

  • Case coupled noise immunity

  • Reverse voltage protection

  • Line to electronics ground surge protection on all lines

  • Transducer cable has ground wire built-in to help you learn what the upgraded transducer content means in practical use: simpler grounding and more reliable signal performance

  • Ground clamp provided for transducer to cable grounding

Related Posts

Why should a homeowner consider a Constant Pressure system for home applications?

Product Literature

Aquavar SOLO2 Installation Guide

Goulds Aquavar Installation and Troubleshooting

Goulds Aquavar Propak Brochure

Goulds Aquavar Propak, 30-80hz Specifications

Goulds Aquavar Solo 2 Instruction Manual

Goulds Variable Speed Controller Hazard Statement

Technical Brochure

More Information
Phase3
Wire Count3 Wire
Motor Horsepower1.5
Stages 10
Well Depth240
Sourcehttps://www.xylem.com/
Model #10GP0715
ManufacturerGoulds
Performance ChartNone
Shipping Weight56
Warranty3 Year Limited
Write Your Own Review
You're reviewing:Goulds Balanced Flow Constant Pressure System, 1.5HP Motor 10GPM at 60PSI - 240ft
Your Rating
Goulds Balanced Flow Constant Pressure System, 1.5HP Motor 10GPM at 60PSI - 240ft
What is included in this ProPak kit?
It includes a Goulds 10GS07 GS water end, a CentriPro 1.5 HP 230 V three-phase motor, and a CentriPro Aquavar SOLO controller with transducer.
What is the flow and pressure rating of this system?
This system is rated for 10 GPM at 60 PSI.
What well depth is this system designed for?
It is designed for wells up to 240 feet deep.
What power configuration does this system use?
It uses a 1.5 HP three-phase motor at 230 V and is listed as 3 wire.
Does this system need a large pressure tank?
No. The product information states that only a small inline pressure tank is needed.
Can the controller be mounted outdoors?
Yes. The wall-mounted controller is Nema 3 rated and can be mounted outside.
What pressure adjustment range is listed?
The system offers a 0-100 PSI pressure setting with finger-controlled adjustments.
What diagnostic protections are mentioned?
The self-diagnostic controls check for dry well, ground fault, short circuit, disconnected lead, high pressure sensor, and temperature fault conditions.

Installation Brief

This constant pressure system includes a pump, motor, and controller package for well system installation.

  1. Confirm the model and well depth match the application, including the 240 foot well depth rating.
  2. Install the Goulds GS water end, CentriPro motor, and Aquavar SOLO controller with transducer as a complete system package.
  3. Mount the wall controller in an appropriate location; the product information states the Nema 3 controller can be mounted outside.
  4. Connect the system using the specified 230 V, 3-wire, three-phase motor configuration.
  5. Add the small inline pressure tank required for system operation and set the desired pressure within the stated adjustment range.
Goulds Balanced Flow Constant Pressure System, 1.5HP Motor 10GPM at 60PSI - 240ftGoulds Balanced Flow Constant Pressure System, 1.5HP Motor 10GPM at 60PSI - 240ft