10' WaterPro Well Stop Sensor - 230v

CLICK HERE TO CONFIRM THE PRICE
$195.70
SKU#
8070
In stock
8070
Features
  • Bottom-mounted probes detect water as shallow as 1/16 in.
  • The relay stops the pump without a valve in the water line.
  • A green light shows when pump power is available; a red light identifies a leak shutdown.
  • A manual reset keeps the pump from restarting just because the water dries up.

The Alderon WaterPro Well Stop 8070 is a well pump leak sensor for hardwired 230 VAC systems. Its 10 ft bare-lead cable connects to the pressure-switch circuit, and its 15 A relay stops the pump when water reaches the sensor.

The Alderon Industries WaterPro Well Stop 8070 is an indoor leak sensor that shuts off a well pump when water reaches both probes on the bottom of the sensor. Its built-in relay interrupts the pressure-switch circuit, stopping the pump from feeding the leak. It does not close a valve in the water line.

Choose the 8070 for a hardwired 230 VAC installation. If the pressure switch controls the pump directly, confirm that the pump load is within the 15 A rating and that the 10 ft cable reaches a spot where leaking water will collect. After a trip, the pump stays off until the leak condition clears and someone resets the sensor.

Specifications

  • Supply voltage: 230 VAC
  • Switching rating: 15 A
  • Cable: 10 ft, 14 AWG, three-conductor SJOOW with bare leads
  • Preset detection depth: 1/16 in. of water at the probes
  • Sensing circuit: two stainless steel probes supplied with 12 VDC by an isolated Class 2 transformer
  • Housing: ABS plastic; indoor use only
More Information
Voltage230v
Model #8070
ManufacturerAqua Science
Shipping Weight5
WarrantyThree-Year Limited Warranty
Write Your Own Review
You're reviewing:10' WaterPro Well Stop Sensor - 230v
Your Rating
pdf
(Size: 3.35 MB)
pdf
(Size: 1.08 MB)
Does the 8070 shut off the water line or just the well pump?
It stops the pump electrically. The relay interrupts the pressure-switch circuit; the sensor does not close the water line.
My pump plugs into a 230 V outlet. Is this the plug-in sensor?
No. The 8070 has bare leads for hardwiring. Alderon's 230 VAC Well Stop with a piggyback plug is part number 8072.
Can the 8070 switch a pump drawing more than 15 A?
Not directly. The relay is rated for 15 A. Have the installer check the pump load before selecting a direct pressure-switch connection.
Where should the sensor sit to detect a leak?
Place it indoors where leaking water will collect under both probes. It detects water at that spot, not a pressure drop elsewhere in the plumbing. For direct connection to the pressure switch, the sensor must be within 10 ft of the switch.
Do the probes operate at 230 V?
No. The 230 VAC rating applies to the supply circuit. An isolated Class 2 transformer supplies the sensing probes with 12 VDC.
Does the green Power light mean the pump is running?
No. Green means power is available to the pump. The red Well Pump Stop light means the sensor has tripped and interrupted pump power.
How do I restore pump operation after a leak?
Clear the leak condition, dry both probes and press Reset on top of the sensor. Check that the green light returns. Neither evaporation nor cycling the power clears a tripped alarm.
Which connector do I need to supply for a pressure-switch installation?
Supply one 1/2 in. Romex cable connector. Alderon provides the bare-lead model with two ring terminals and a two-wire Wago connector; those do not replace the cable connector.
Can the 8070 shut down a pump through a starter box?
Alderon shows the 8070 in the pilot circuit of a deluxe capacitor starter box in Figure 22 of the manual. The installer must verify that the magnetic contactor coil is rated for 230 VAC and check the starter panel's own schematic.
How do I test and maintain the sensor?
Test it monthly using the shallow-dish test on page 7 of the manual. Water touching both probes should turn on the red light and interrupt pump power. Dry the probes and press Reset after the test. Keep both probes free of mud, soap residue and mineral deposits.
Need help finding the right solution for your water system or have questions about this item? Call Aqua Science at 800-767-8731. Our knowledgeable team is happy to help you with product selection, compatibility, and technical questions.

Installation Brief

This WaterPro Well Stop Sensor is installed in-line with a pressure switch and powered as a 230VAC bare lead model.

  1. Mount and field install the sensor according to the system layout.
  2. Connect the bare lead model in-line with the pressure switch.
  3. Power the sensor and confirm the green LED illuminates to show normal powered operation.
  4. After setup, verify the reset pushbutton and alarm indication are accessible for service.
10' WaterPro Well Stop Sensor - 230v10' WaterPro Well Stop Sensor - 230v