Trojan UV Quartz Sleeve for UVMAX-28E,  PRO 7 or UVMAX-E4

Trojan UV Quartz Sleeve for UVMAX-28E, PRO 7 or UVMAX-E4

GreensandPlus Filter System with 9" X 48" Tank & Aqua Science 89 Digital Control Valve

$765.00

Helps to Remove
Iron, Manganese, Hydrogen Sulfide, Arsenic and Radium

Features and Benefits

• The manganese dioxide-coated surface of GreensandPlus acts as a catalyst in the oxidation-reduction reaction of iron and manganese.
• The silica sand core of GreensandPlus allows it to withstand waters that are low in silica, TDS, and hardness without breakdown.
•Effective at higher operating temperatures and higher differential pressures than standard manganese greensand.
•GreensandPlus is an exact replacement for manganese greensand.
•GreensandPlus has the WQA Gold Seal Certification for compliance with NSF/ANSI 61

*Shipping Included*
Availability:In stock

Oxygen Chamber System (AIO) technology uses natural oxidation to remove Iron from the water supply, without chemicals, without aerators and without air compressors.

This system includes:

Aqua Science 89Digital Control Valve
9x48 Fiberglass Mineral Tank
1" by-pass
1 Cu. ft of Manganese Greensand Plus
1 Sleeve of gravel
1.05" Riser Tube
Funnel and Cap 


Iron and Manganese Removal
GreensandPlus™ has a manganese dioxide coating which creates a highly oxidative environment.  When a strong oxidant is injected in the raw water stream ahead of a GreensandPlus™ filter, soluble iron and manganese are easily oxidized and the precipitates are trapped by the media (which acts as a catalyst and does not participate in the reaction). The filter is subsequently backwashed and reused, therefore it is not sacrificed in this process.

Hydrogen Sulfide Removal
GreensandPlus™ directly oxidizes sulfide and catalyzes the oxidation reaction. Increased run length and service life of GreensandPlus™ may be realized by pre-feeding a solution of chlorine-containing compounds.

Arsenic Removal
GreensandPlus™ can be used to remove arsenic from ground water in the presence of iron. Chlorine must be pre-injected to oxidize the iron and convert arsenite to arsenate and keep the media regenerated.

Arsenic combines with oxidized iron and is filtered out in the media. If there is not a sufficient amount of iron present in the raw water, then an iron salt such as ferric chloride can be pre‑injected.

A general guideline is 1 mg/L of iron to remove 20 µg/L of arsenic. This can vary greatly depending on pH, silica, and other competing ions in the water.

Radium Removal
GreensandPlus™ can be used to remove radium from ground water in the presence of manganese, in a similar manner to arsenic removal. In the case of radium, manganese in the raw water is necessary.

If there is not a sufficient amount of manganese present, then manganese sources such as manganous sulfate can be pre‑injected.

More Information
Model #MGSPAS899x48
ManufacturerAqua Science
Shipping Weight150
Flow Rate0
MaterialManganese Greensand Plus
Size9" X 48"
Control Valve89 Digital
WarrantyLifetime Mineral Tank Warranty